Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Equine Vet Sci ; 136: 105074, 2024 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-38648909

RESUMEN

The aim of this study was to evaluate the intraocular pressure (IOP) measurements obtained from first, second, and third probe-cornea touch (PCT) and compare them with the average of six PCTs using two rebound tonometers in horses. This study enrolled a total of thirty-eight stallions, comprising of 24 Arabian horses and 14 cross-breeds (with an average age of 8 ± 3 years). The IOP measurements of first, second, and third, as well as the average of six PCTs were obtained using either Tonovet (TV) or Tonovet Plus (TV+) rebound tonometers. The mean differences (95% limits of agreement) between the average of six PCTs and the first, second, and third PCTs were 0.1 (-4.8 to 5), 0.2 (-4.8 to 4.5), and 0.2 (-3.6 to 4.0) mmHg with TV, respectively. With TV+, the differences were 0.3 (-6.6 to 7.2), 1.1 (-8.6 to 10.8), and -0.2 (-3.6 to 4.0) mmHg, respectively. Compared to the average of six PCTs, only 89.5%, 92.1%, and 97.4% of IOP measurements obtained from TV and 78.9%, 73.3%, and 65.8% of IOP measurements obtained from TV+ were within 4 mmHg of the average of six PCTs for first, second, and third PCTs, respectively. In conclusion, the measurement of IOP in the first PCT achieved best agreement with the IOP measurement of six average PCTs. Therefore, the first PCT could be considered as an alternative option for measuring IOP in horses when obtaining an average of six PCTs is not feasible.

2.
N Z Vet J ; 71(5): 251-258, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37306141

RESUMEN

AIMS: To compare intraocular pressure (IOP) measurements obtained in rabbits using rebound (TV) and applanation (TPV) tonometers with four different methods of physical restraint. METHODS: A total of 20 New Zealand White rabbits (40 eyes) were included in this study. IOP readings were obtained from both eyes using the two different tonometers. The rabbits were placed on a table and restrained by wrapping in a cloth (Method I), by scruffing with rear support (Method II), by wrapping in a cloth and cupped in the hands (Method III), or by a box restrainer (Method IV). RESULTS: The mean IOP measurement obtained by TPV was higher than that obtained with the TV for all handling methods. Mean differences (TV-TPV, in mmHg) in IOP were -5.3 (95% Cl = -6.5 to -4.1) for Method 1, -4.7 (95% Cl = -6.2 to -3.29) for Method II, -4.9 (95% Cl = -6.2 to -3.7) for Method III and -7.6 (95% Cl = -9.2 to -5.9) for Method IV. Using the TV tonometer, mean IOP for Method IV was higher than for Method I (mean difference 2.1 (95% Cl = 1.1-3.1)), whereas using the TPV tonometer, mean IOP for Method IV was significantly higher than Method I, II, and III (mean differences: 4.4 (95% Cl = 2.6-5.9), 3.7 (95% Cl = 2-5.3) and 3.8 (95% Cl = 2-5.4), respectively). According to Bland-Altman plots, IOP readings for TPV tended to be higher than those for TV with all handling methods, but with a lack of agreement. The mean difference and 95% limits of agreement for the differences between TV and TPV were -5.4 mmHg (-12.5-1.9 mmHg), -4.7 mmHg (-12.9-3.5 mmHg), -4.9 mmHg (-12-2.2 mmHg), and -7.5 mmHg (-17.4-2.3 mmHg), with Methods I, II, III, and IV, respectively. Comparing TV and TPV, only 7.5%, 12.5%, 27.5%, and 15% of IOP measurements from 20 rabbits were within the range considered clinically acceptable for IOP (± 2 mmHg) for Method I, II, III, and IV, respectively. CONCLUSION AND CLINICAL RELEVANCE: In conclusion, the physical restraint method should be recorded when IOP is measured in rabbits, and TV and TPV tonometers cannot be used interchangeably (high bias and low proportion of measurements within ± 2 mmHg).


Asunto(s)
Presión Intraocular , Tonometría Ocular , Animales , Conejos , Tonometría Ocular/instrumentación , Tonometría Ocular/métodos , Tonometría Ocular/veterinaria , Restricción Física , Masculino , Femenino
3.
N Z Vet J ; 70(3): 159-164, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34890521

RESUMEN

AIMS: To compare alternative methods of recording body temperature (BT) with rectal temperature (RT) in clinically healthy dogs. METHODS: This prospective study included 97 healthy mixed-breed dogs (43 females and 54 males). The gingival temperature (GT) was collected by using a human non-contact, infrared forehead thermometer, while ocular temperature (OT) and metacarpal pad temperature (MPT) were obtained with an infrared thermal camera. The degree of agreement was determined using the Bland-Altman method, with RT considered as the reference temperature. RESULTS: A total of 382 readings were obtained from four different anatomical regions. The mean difference and their 95% limits of agreement for the differences between RT-GT, RT-OT, and RT-MPT were 0.18°C (-0.95°C-1.32°C), 0.79°C (-0.45°C-2.04°C), and 0.50°C (-0.63°C-1.62°C), respectively. The GT, OT, and MPT values were within ±0.5°C of RT for 65.9%, 19.5%, and 52.5% of dogs, respectively. CONCLUSIONS AND CLINICAL RELEVANCE: Although GT, OT, and MPT were a quick way to estimate BT in dogs, these measurements were not comparable with RT. The GT measurement achieved the best agreement with RT measurement (lowest bias and the highest proportion of measurements within ±0.5°C). The GT could be considered an option for monitoring changes to body temperature in clinically healthy dogs where RT measurement is not possible.


Asunto(s)
Temperatura Corporal , Termómetros , Animales , Perros , Femenino , Masculino , Estudios Prospectivos , Recto , Temperatura , Termómetros/veterinaria
4.
J Dairy Sci ; 93(8): 3525-32, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20655420

RESUMEN

The objectives of this experiment were to determine interrelationships among mastitis indicators and evaluate the subclinical mastitis detection ability of infrared thermography (IRT) in comparison with the California Mastitis Test (CMT). Somatic cell count (SCC), CMT, and udder skin surface temperature (USST) data were compiled from 62 Brown Swiss dairy cows (days in milk=117+/-51, milk yield=14.7+/-5.2 kg; mean +/- SD). The CORR, REG, and NLIN procedures of Statistical Analysis System (SAS Institute Inc., Cary, NC) were employed to attain interrelationships among mastitis indicators. The diagnostic merit of IRT as an indirect measure of subclinical mastitis was compared with CMT using the receiver operating characteristics curves. The udder skin surface temperature was positively correlated with the CMT score (r=0.86) and SCC (r=0.73). There was an exponential increase in SCC (SCC, x10(3) cells/mL=22.35 x e(1.31 x CMT score); R(2)=0.98) and a linear increase in USST (USST, degrees C=33.45+1.08 x CMT score; R(2)=0.75) as the CMT score increased. As SCC increased, USST increased logarithmically [USST, degrees C=28.72+0.49 x ln(SCC, x10(3) cells/mL); R(2)=0.72]. The USST for healthy quarters (SCC 400,000 cells/mL; n=135) (mean +/- SE; 33.45+/-0.09 vs. 35.80+/-0.08 degrees C). The sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, positive predictive value, and negative predictive value were 95.6, 93.6, 14.97, 0.05, 95.0, and 93.6, respectively, for IRT and 88.9, 98.9, 83.56, 0.11, 99.2, and 86.1, respectively, for CMT. The area under the receiver operating characteristics curve for IRT and CMT was not different. In conclusion, as a noninvasive and quick tool, IRT can be employed for screening subclinical mastitis via measuring USST, with a high predictive diagnostic ability similar to CMT when microbiological culturing is unavailable. However, the reliability of IRT among cows with different characteristics and those living under various environmental conditions remains to be determined.


Asunto(s)
Tamizaje Masivo/veterinaria , Mastitis Bovina/diagnóstico , Termografía/veterinaria , Animales , Bovinos , Recuento de Células/veterinaria , Femenino , Glándulas Mamarias Animales/fisiología , Tamizaje Masivo/métodos , Sensibilidad y Especificidad , Temperatura Cutánea , Termografía/métodos
5.
Res Vet Sci ; 87(1): 102-5, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19062054

RESUMEN

The pharmacokinetic disposition and bioavailability of florfenicol (FF) were determined after single intravenous (i.v.) and intramuscular (i.m.) administrations of 25mg/kg b.w. to ten healthy New Zealand White rabbits. Plasma FF concentrations were determined by high-performance liquid chromatography (HPLC). The plasma pharmacokinetic values for FF were best described by a one-compartment open model. The elimination half-life (t(1/2beta)) was different (p<0.05) however, the area under curve (AUC) was similar (p>0.05) after i.v. and i.m. administrations. FF was rapidly eliminated (t(1/2beta) 1.49+/-0.23 h), slowly absorbed and high (F, 88.75+/-0.22%) after i.m. injection. In addition, FF was widely distributed to the body tissues (V(ss) 0.98+/-0.05 L/kg) after i.v. injection. In this study the time that plasma concentration exceeded the concentration of 2 microg/mL was approximately 6h. For bacteria with MIC of 2 microg/mL, frequent administration at this dose would be needed to maintain the concentration above the MIC. However, it is possible that rabbit pathogens may have MIC values less than 2 microg/mL which would allow for less frequent administration. Further studies are necessary to identify the range of MIC values for rabbit pathogens and to identify the most appropriate PK-PD parameter needed to predict an effective dose.


Asunto(s)
Antibacterianos/administración & dosificación , Antibacterianos/farmacocinética , Tianfenicol/análogos & derivados , Animales , Antibacterianos/sangre , Área Bajo la Curva , Semivida , Inyecciones Intramusculares , Inyecciones Intravenosas , Conejos , Tianfenicol/administración & dosificación , Tianfenicol/sangre , Tianfenicol/farmacocinética
6.
J Dairy Sci ; 91(11): 4244-8, 2008 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-18946129

RESUMEN

Infrared thermography (IRT) absorbs infrared radiation and generates images based on the amount of heat generated. It has been used in human medicine for diagnosis of various cancers. This experiment was conducted to determine if IRT had merit for early detection of subclinical mastitis in dairy cows. Milk sample and skin surface temperature (SST) were simultaneously evaluated using the California Mastitis Test (CMT) and IRT for each quarter in 94 dairy cows (49 Brown Swiss and 45 Holstein). Average days in milk (DIM) and milk production were 93 +/- 37 d and 16 +/- 2.2 kg (mean +/- SD) and their ages ranged from 4 to 8 yr. There was a strong correlation between SST and CMT score (r = 0.92). Average SST was 33.19, 34.08, 34.99, and 36.15 degrees C for quarters with the CMT score of 0 (n = 156), +1 (n = 116), +2 (n = 80), and +3 (n = 24), respectively. This association was best described by a linear model as follows: y = 0.94x + 33.17, R(2) = 0.85, where y = SST and x = CMT score. Changes in rectal temperature (RT) due to the CMT score were minor (y = 0.09x + 38.39, R(2) = 0.07, where y = RT and x = average CMT score). In conclusion, RT may not confirm mastitis. However, IRT is sensitive enough to perceive changes in SST in response to varying degrees of severity of the mammary gland infection as reflected by the CMT score, suggesting that as a noninvasive tool, IRT can be employed for screening dairy cows for mastitis.


Asunto(s)
Rayos Infrarrojos , Mastitis Bovina/diagnóstico , Termografía/veterinaria , Animales , Bovinos , Femenino , Temperatura Cutánea
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...